SAFETY GUIDE - MAXIMUM TEMPERATURE LIMITS
|
The follwing RYCO Hose Series are not listed on this page: T1F, TJ2D, RQG1, M2G,
M1, FB2, RTH1, TW1, PW2, MP1.
These hoses are specific purpose hoses, and their
temperature limits are specified in the HOSE section of this Product Technical Manual.
Refer to RYCO Hydraulics Technical Department for any further queries.
Other RYCO
Hose Series are listed below.
The Maximum Working Temperatures for these hoses as
listed in the HOSE section of this Product Technical Manual; are for use with general
purpose, mineral (petroleum) oil based hydraulic fluids, except where otherwise
stated.
Temperature limits for other hydraulic fluids, and some other common applications,
are listed below. |
CAUTION:
Life expectancy of hoses is shortened at high temperatures. Detrimental
effects increase when temperature is elevated, and when operating pressure, flow
velocity, duration and frequency of exposure, and level of impurities in the media
are high. Actual service life at temperatures approaching the recommended limits
will depend on the particular application and the fluid being used.
Maximum Working
Temperatures refer to the temperature of the media in the hose; not the environmental
temperature of around the outside of the hose. Please refer to RYCO Hydraulics Technical
Department for environmental temperatures in excess of 80°C 176°F), except RQP1 and RQP2 Series where environmental temperature is the same as media temperature. |
Maximum Working Temperatures shown are for continuous temperatures. Slightly higher
intermittent temperatures (up to 10% of total operating time) may be acceptable
with some hoses and some fluids if reduced service life is acceptable. Please refer
to RYCO Hydraulics Technical Department for more information.
DO NOT expose hose
to maximum temperature and maximum rated working pressure at the same time.
The
fluid manufacturer's recommended maximum operating temperature for the fluid must
not be exceeded. If different to the below listed temperatures, the lower limit
must take precedence. We recommend keeping the hose filled with the pressure medium
at all times. Further information available on request. |
|
|
|
GROUP 1 |
GROUP 2 |
GROUP 3 |
GROUP 4 |
|
AVENGER
|
T1A, T2A, T3KA HSHA, HSPA |
H12A, H13A |
|
|
|
DIEHARD
|
T1D, T2D, T3KD, TXA2D |
H12D, H13D, H15D |
|
|
|
SLIDER
|
T2S |
H12S, H13S |
|
|
|
SURVIVOR
|
RQP6 |
|
RQP1, RQP2, RQP5 |
|
|
OTHER SERIES
|
DF2A, SR, SRF, M2, T5 |
|
|
RT7, RT7N, RT7T, RT7TN
RT8, RT8N, RT8T, RT8TN
PL1 |
| MEDIA |
TEMPERATURE LIMITS |
GENERAL PURPOSE
MINERAL (PETROLEUM)
BASED HYDRAULIC OIL
(see Note 1) |
-40°C to +100°C
(-40°F to +212°F)
RQP6: -40° to +125°C
(-40°F to +257°F) |
-40°C to +121°C
(-40°F to +250°F)
|
-40°C to +150°C
(-40°F to +302°F) |
-40°C to +95°C
(-40°F to +203°F)
|
| WATER |
+71°C (+160°F) |
0°C to +71°C
(+32°F to +160°F)
|
0°C to +121°C
(+32°F +250°F)
|
0°C to +70°C
(+32°F to +158°F)
|
WATER IN MINERAL OIL
(40% to 80% water) |
+85°C (+185°F) |
-40°C to +85°C
(-40°F to +185°F)
|
-40°C +121°C
(-40°F +250°F)
|
-40°C to +95°C
(-40°F to +203°F)
|
MINERAL OIL IN WATER
(more than 80% water) |
+85°C (+185°F) |
-40°C to +85°C
(-40°F to+185°F) |
-40°C to +121°C
(-40°F to +250°F)
|
-40°C to +70°C
(-40°F to +158°F)
|
| WATER / GLYCOL |
+85°C (+185°F) |
-40°C to +85°C
(-40°F to +185°F)
|
-40°C to +121°C
(-40°F to +250°F)
|
-40°C to +70°C
(-40°F to +158°F)
|
| GLYCOL |
+85°C (+185°F) |
-40°C to +85°C
(-40°F to +185°F)
|
-40°C to+85°C
(-40°F to +185°F)
|
-40°C to+70°C
(-40°F to +158°F)
|
PHOSPHATE ESTERS
(see Note 2) |
Not suitable
|
Not suitable |
-40°C to +82°C (see Note 2)
(-40°F to +180°F) (see Note 2) |
Not suitable |
|
AIR (see Note 3)
|
RQP6: -40°C to +100°C
(-40°F to +212°F)
***OTHERS:
+71°C (+160°F)
|
-40°C to +71°C (see Note 3)
(-40°F to +160°F) (see Note 3)
|
-40°C to +121°C (see Note 3)
(-40°F to +250°F) (see Note 3)
|
-40°C to +71°C (see Note 3)
(-40°F to +160°F) (see Note 3)
|
| PETROL (GASOLINE) |
Contact RYCO Hydraulics |
Contact RYCO Hydraulics |
Contact RYCO Hydraulics |
Contact RYCO Hydraulics |
| DIESEL FUEL |
T5: +71°C (+160°F)
RQP6: -40°C to +71°C
(-40°F to +160°F)
OTHERS: +50°C (+122°F) |
-40°C to +50°C
(-40°F to +122°F) |
-40°C to +93°C
(-40°F to +200°F) |
T5: -40°C to +71°C
(-40°F to +160°C)
PL1: -40°C to +49°C
(-40°F to +120°F) |
ENGINE LUBRICATING OIL,
GEARBOX OIL |
-40°C to +100°C
(-40°F to +212°F)
|
-40°C to +100°C
(-40°F to +212°F)
|
-40°C to +100°C
(-40°F to +212°F)
|
-40°C to +95°C
(-40°F to +203°F)
|
AUTOMATIC
TRANSMISSION FLUID |
-40°C to +100°C
(-40°F to +212°F)
|
-40°C to +100°C
(-40°F to +212°F)
|
-40°C to +100°C
(-40°F to +212°F)
|
-40°C to +95°C
(-40°F to +203°F)
|
|
|
Note 1
|
For highly refined and special purpose mineral based hydraulic oils (for example
aviation hydraulic oils, MIL spec oils, etc), contact RYCO Hydraulics Technical
Department. |
|
Note 2
|
Not suitable for use with aerospace type phosphate esters such as Monsanto Skydrol
500B, Stauffer Aero-Safe 2300W and Chevron Hy-jet IV. |
|
Note 3
|
For use with Air at pressures above 17,2 bar (250 psi), cover of hose must be perforated/pin-pricked
(except RQP5 and T5), to allow air permeating through hose to escape without blistering
the cover. Maximum working pressure of wire braid and spiral reinforced hose must
be reduced by 30% (except for RQP1 and RQP2). Observe all State and Federal Safety
Regulations. |
|
|
|
|
|