Page 115 - 2019 PRODUCT TECHNICAL MANUAL - HYDRAULICS V4-8
P. 115
RECOMMENDED FOR:
High pressure hydraulic oil applications where pressure or temperature requirements exceed the performance requirements of SAE 100R1AT and DIN 20022-1SN. May be used with compressed air if cover of hose is perforated (pin- pricked) and additional Safety Devices are used.
PERFORMANCE:
Meets or Exceeds the Performance Requirements of: AS 3791 100R1AT, DIN 20022-1SN, EN 853 Type 1SN, ISO 1436 Types R1AT & 1SN, SAE 100R1AT.
TUBE:
Black, synthetic rubber, specifically compounded for temperature resistance and multi fluid resistance.
REINFORCEMENT:
One braid of high tensile steel wire.
COVER:
SURVIVOR, blue, oil resistant and abrasion resistant synthetic rubber.
No skiving required with T2000 Series Crimp Couplings and K000 Series Field Attachable Couplings*.
MSHA - FLAME RESISTANCE:
Meets Flame Resistant Designation “U.S. MSHA” of the US Department of Labor, Mine Safety and Health Administration. Complies with Flame Resistant requirements of Australian Standard AS 2660 and Method of Test AS 1180.10B.
TEMPERATURE RANGE:
From -40°C to +150°C (-40°F to +302°F).
For water, water/oil emulsions, diesel fuels, glycol, see page 58.
WORKING PRESSURE:
Maximum working pressures are based on 4:1 safety factor (maximum working pressure to minimum burst pressure).
THIRD PARTY APPROVALS:
ABS, DNV-GL, LR, MED, USCG, GOST-R, BV, RINA and KR.
COUPLINGS:
NON-SKIVE ONE-PIECE CRIMP
T2000 Series (sizes -04 to -16) pages 189 to 234. Assembly Instructions pages 480.
FIELD ATTACHABLE NON-SKIVE*
6000 SERIES insert (sizes -04 to -16) pages 252 to 273. K000 Series ferrule (sizes -04 to -16) page 355. Assembly Instructions page 478.
SPECIALTY AND HIGH TEMPERATURE
RQP1
HIGH TEMPERATURE MULTI FLUID
ONE WIRE BRAID HOSE
RQP1 – SURVIVOR NON-SKIVE HOSE
PART NO
HOSE SIZE
NOMINAL HOSE ID
NOMINAL HOSE OD
MAXIMUM WORKING PRESSURE
MINIMUM BURST PRESSURE
MINIMUM BEND RADIUS
AVERAGE WEIGHT
COUPLING SERIES
ONE PIECE
FIELD ATT
Hose DN Dash mm inch RQP15 8 -05 8,2 5/16 RQP18 12 -08 13,0 1/2
RQP112 19 -12 19,1 3/4
mm inch
15,0 0.59 20,5 0.81 27,6 1.09
bar psi bar psi mm inch kg/m lb/ft
215 3120 860 12500 114 4.5 0,27 0.18 T2000 160 2300 640 9300 178 7.0 0,44 0.30 T2000 120 1740 480 7000 240 9.5 0,64 0.43 T2000
NON-SKIVE
6000 (K000) 6000 (K000)
RQP14
6
-04
6,6
1/4
13,4
0.53
225
3250
900
13000
100
4.0
0,24
0.16
T2000
6000 (K000)
RQP16
10
-06
9,8
3/8
17,4
0.69
180
2600
720
10400
125
5.0
0,34
0.23
T2000
6000 (K000)
RQP110
16
-10
16,2
5/8
23,7
0.93
130
1880
520
7540
200
8.0
0,51
0.34
T2000
6000 (K000)
RQP116
25
-16
25,4
1
35,7
1.41
90
1300
360
5200
300
12.0
0,98
0.66
T2000
6000 (K000)
*
Field Attachable Couplings should not be used on RQP1 Hose at maximum working pressure when temperature exceeds 121˚C (250˚F). Field Attachable Couplings may be used on RQP1 Hose at over 121˚C but at reduced working pressure. Contact RYCO for more information.
Refer to the latest RYCO Crimp Charts for crimp diameter and mark lengths.
HIGHER TECHCNOONLNOEGCYTEINQUGAPLASRGTNREARTSEHRIPPSERFORMANCE 113
TECHNICAL ADAPTORS COUPLINGS HOSE INTRODUCTION