Page 486 - 2019 PRODUCT TECHNICAL MANUAL - HYDRAULICS V4-8
P. 486
TECHNICAL
PUSH-ON HOSE ASSEMBLY
ASSEMBLY INSTRUCTIONS FOR:
8000 SERIES PUSH-ON COUPLINGS. USE ONLY RYCO PL1D, PL1V and RQP6 SERIES HOSE.
STEP ONE
90°
• Cut hose to required length with a sharp knife.
• Lightly lubricate inside of hose and outside of the hose barb.
STEP TWO
• Push hose onto fitting until hose end bottoms underneath cap as shown.
STEP THREE
• If hose assembly is to be used at above 50% of Maximum Working Pressure, or in a potentially dangerous or critical application,
a clamp must be used.
• Do not overtighten clamp as this may damage hose.
REMOVING COUPLINGS, STEP ONE
• Remove clamp if fitted.
• Slit hose length-wise, from cap to end of hose tail.
REMOVING COUPLINGS, STEP TWO
• Sharply bend hose and remove.
484 HIGHER TECHNOLOGYRYECQOUAQLUSALGIRTEYATER PERFORMANCE