ASSEMBLY INSTRUCTIONS FOR:
RYCO FIELD ATTACHABLE COUPLINGS WITH MATCHED SIZES OF RYCO NON-SKIVE HOSE.
USE ONLY RYCO BT1, E2, M2, M2G, RQP1, RQP2, RQP5, T1A, T1D, T1F, T2A, T2D, TXA2D, T5 and TPGL SERIES HOSE
STEP ONE:
Cut hose to length required using a cut-off saw.
Ensure hose is cut squarely.
Clean hose bore.
STEP TWO:
Lightly lubricate outer cover.
STEP THREE:
Screw anti-clockwise until hose bottoms in ferrule. Ease back between 1/2 and 3/4 of a turn (Note: This is not required for P000-02 ferrule with TPGL hose).
STEP FOUR:
Lightly lubricate insert and inside of hose.
Note: Do not use lubricant for M2G hose, or hose to be used with volatile gases.
STEP FIVE:
Screw insert clockwise right into ferrule using a continuous motion.
Do not allow hose to turn during operation.
SPECIAL NOTES:
- For T1A and T1D Hose in sizes -20, -24, -32 In these sizes, K Series Ferrules are not available and A Series Field Attachable Couplings may be used. The cover of hose must be skived at ends. Refer to page 497 for assembly instructions.
- For T2A, T2D and RQP2 Hose in sizes -24, -32 In these sizes, L Series Ferrules are not available and B Series Field Attachable Couplings may be used.The cover of hose must be skived at ends. Refer to page 497 for assembly instructions.
- Field Attachable Couplings should not be used at maximum working pressure of hose when temperature exceeds 121°C (250°F). Field Attachable Couplings may be used on suitable hose at over 121°C (250°F) but at reduced working pressure.
Contact RYCO Technical Department for more information.