SRF & SR Hoses Assembly Instructions and Safety Tips

SR & SRF Hoses

ASSEMBLY INSTRUCTIONS FOR:

33000 SERIES SERIES SUCTION HOSE COUPLINGS. USE ONLY MATCHED SERIES OF RYCO SR and SRF SERIES HOSE.

STEP ONE:

006_2_step_one

Cut hose to required length using a cut-off saw.
Ensure helix wires are not protruding.
Ensure hose is cut squarely.

STEP TWO:

006_2_step_two

Mark the cover of the hose to ensure that Clamp will be correctly located.

STEP THREE:

006_2_step_three

Slide Clamp over hose.
Push the coupling into the hose bore until hex or collar abuts end of hose.
Position Clamp, and tighten bolt to recommended torque.