ALL SERIES (EXCEPT V SERIES)

EXAMPLE 1  To order 1/2” NPT male Insert and Ferrule for 1/2” two wire non-skive hose (T2D).

(a) Individually

Order Insert 6090-0808 (6000 Series). See NPT 6000 Series Inserts on page 360. Order Ferrule L000-08.

L000 Series Ferrules are used on T2D hose; see table on the previous page, or table for Matched Couplings for T2D on page 101.

Dash Size -08 part of L000-08 comes from 1/2” hose = 8/16” = -08; or from the tables.

(b) Complete Coupling

Order L090-0808.

Simply replace the first character of the Insert part number with the first character of the Ferrule part number.

(replace 6 with L) = 6090-0808 »» L090-0808

How-to-order-ryco-field-attachable-couplings-img01
EXAMPLE 2  To order 3/4”-16 JIC female Insert and Ferrule for 3/8” RQP1 series hose.

(a) Individually

Order Insert 6040-0612 (6000 Series). See JIC 6000 Series Inserts on page 364.

Order Ferrule K000-06.

K000 Series Ferrules are used on RQP1 hose; see table on previous page, table for Matched Couplings for RQP1 on page 111.

Dash Size -06 part of K000-06 comes from 3/8” hose = 6/16” = -06; or from the tables.

(b) Complete Coupling

Order K040-0612.

Simply replace the first character of the Insert part number with the first character of the Ferrule part number.

(replace 6 with K) = 6040-0612 »» K040-0612

How-to-order-ryco-field-attachable-couplings-img02

* See page 341 for How To Order RYCO V000 Series Field Attachable Couplings for RQP5 and T5 Series Hose.

CUT-OFF ALLOWANCE (CA) DIMENSIONS FOR FIELD ATTACHABLES

Due to differences in Ferrule design, many Cut-Off Allowance (CA) dimensions vary between each Ferrule Series for the same matched Insert/Hose size.

The Cut-Off Allowance (CA) dimensions published in “6000 Series Field Attachable Inserts” section allow for the Ferrule being eased back 5/8 of a turn after the hose has bottomed in the ferrule, as per “Field Attachable Assembly Instructions” (ease back between 1/2 and 3/4 of a turn).

The Cut-Off Allowance (CA) values for 6000 Series Inserts, published in the tables on pages 357 to 387 are:
Up to and including -20 Size; the CA is for L000 Series (the most popular series)

To determine the correct Cut-Off Allowance (CA) for other Ferrule Series, use the published figure from pages 355 to 385, and adjust by the CA Adjustment dimension listed in the table on the previous page.

EXAMPLE:
Determine the Cut-Off Allowance (CA) for K090-0808. From table on page 108, Cut-Off Allowance (CA) for 6090-0808 (L090-0808) is 42 mm. From the table on the previous page, adjustment for K000 Series in -08 size is “add 3 mm”. Cut-Off Allowance (CA) for K090-0808 = 42 mm + 3 mm = 45 mm.

If the hose assembly length is critical, when calculating the Cut Length of hose, you must also allow for an increase in length of hose when the coupling is attached, due to compression within the coupling; see page 466.

For further information about Hose Assemblies and Cut-Off Allowances (CA), see pages 468 to 473 of the Technical Section.